SPV40

产品概述

Features:

Two sets of main contacts + one set of auxiliary contacts

When the main contacts are stuck, the auxiliary contacts shallfulfill the safety detection function (lEC 6181 0-3).

Main contact gap> 3.6 mm, auxiliarycontact gap>0.7 mm

Suitable for inverters used in solar photovoltaic power generation and Ac charging stations.

The coil holding voltage can be reduced to 50-60% of the coil's rated voltage to achieve energy-saving benefits.

产品优势

详细参数

Contact Data

Contact arrangement 2 Form A ,1 Form B
Contact material
AgSn02
Contact resistance

Main contact: 10mQMax(@6VDC 20A)

Auxiliary contact:100mΩMax(@6VDC1A)

Rated load (Resistive)
480VAC 40A
Max.Switching Voltage
480VAC
Max.Switching Curre nt
40A
Max.Switching Power
19,200VA
Min.load
6VDC100mA
Operate time(at rated.volt.)
s30ms
Release time(atrated.volt.)
s10ms

Parameters Data

Environmental requirements:
Complies with RoHS, ELV, and REACHregulations
Insulation Resistance
1000MΩ Min(500vDC)
Dielectric strength
Between open main contacts
2000VAC,50/60Hz 1min.
Between main contact and auxiliary contact
5000VAC,50/60Hz 1min.
Between main contact sets
2000VAC,50/60Hz 1min.
Between auxiliary contact and coil
5000VAC,50/60Hz 1min.
Between main contact and coil
2000VAC,50/60Hz 1min.
Between disconnected auxiliary contact
1000VAC,50/60Hz 1min.
Temperature rise
<70K(After the coil is energized with rated voltage for 100ms,set the holding voltage to 60% of rated voltage, load current carrying 40A, @85°C)
Shock resistance
Destructive    100G Min
Functional   10G Min
Vibration resistance
Destructive  10~55Hz1.5mm DA
Functional  10~55Hz 1.5mm DA
Te mperaturerise
<70K(Afterenergizing the coil at rated voltage for200ms,set the holding voltageto 60% of rated voltage,load current 40A, @85°C)
Mechanical endurance
1x106OPS
Ambient temperature
-40℃C~85℃C(NoCondensation)
Humidity
5% ~ 85%RH
Termination
PCB
Unit weight
Approx.65g