Features:
●2 Main contacts +1 Auxiliary contact.
●Auxiliary contact can detect main contact welding in order to construct a safety circuit( lEC 61810-3)
●Contact gap:Min 3.6mm(Main contact),each contact, Min 1.0mm(Auxiliary contact)
●Applicable to inverters for solar photovoltaic power generation,AC charging piles
●Low coil holding voltage contributes to save energy
Contact Data
Contact arrangement | 2 Form A(Main contact),1Form B(Aux-contact) |
Rated load (Resistive) |
Main contact:40A 480VAC Auxiliary contact:1A 277VAC/1A 30VDC |
Max.Switching current |
Main contact: 40A Auxiliary contact: 1A |
Max.Switching voltage |
Main contact:480VAC Auxiliary contact:30VDC,277VAC |
Max.Switching power |
Main contact: 19200VA Auxiliary contact: 277VA/30W |
Parameters Data
Contact material |
Main contact::AgSn02/AgNi Auxiliary contact:AgNi |
|
Contactresistantce |
Main contact:10mΩ max(@ 6VDC 20A) Auxiliary contact:100mΩ max(@ 6VDC 1A) |
|
Operate time (at nomi.volt .) | 30ms. Max. |
|
Release time (at nomi.volt .) | 10ms. Max. |
|
Insulationresistance | 1000MΩ .(DC500V) |
|
Dielectric strength |
Between open main contacts |
2000VAC,50/60Hz1min. |
Between main contact and auxiliary contact |
5000VAC,50/60Hz1min. |
|
Between main contact sets |
2000VAC,50/60Hz1min. |
|
Between auxiliary contact and coil |
5000VAC,50/60Hz1min. |
|
Between main contact and coil |
2000VAC,50/60Hz1min. |
|
Between disconnected auxiliary contact |
1000VAC,50/60Hz1min. |
|
Temperature rise |
<70K(After the coil is energized with rated voltage for 100ms,set the holding voltage to 60% of rated voltage, load current carrying 40A, @85°C) |
|
Shockresistance |
Functional 98m/s2 |
|
Destructive 980m/s2 |
||
Vibrationresistance |
10Hz to 55Hz1.0mm DA |
|
Mechanicalendurance |
1x106OPS |
|
Ambient temperature |
-40℃ to +85℃ |
|
Humidity |
5% to 85%RH |
|
Termination |
PCB |
|
Weight |
Approx.65g |